Passive house Low-E Glass

Passive house Low-E Glass       Passive house (Passivhaus in Germany) is a kind of passively designed, energy-saving construction. It doesn’t need active heating, but pas

Passive house Low-E Glass

       Passive house (Passivhaus in Germany) is a kind of passively designed, energy-saving construction. It doesn’t need active heating, but passively absorbed heat to keep a comfortable indoor temperature. The house uses heat recycling device to collect energy fromthe sun, human body, home appliances to keep the room warm so it doesn’t need active heat supply. Jinjing High Performance Low-E glass specialized for passive house has superior product performance, and it can guarantee high.

       visible light transmittance while has a extremely low heat transfer coefficient. It is the first choice for energy-saving passive house.

5Solarban 70XL+18Ar+5C+18Ar+5Optilite S1.16

Key indicators :

Coefficient of heat transfer : U Value 0.57W/M .K

blob.png

Certificate :

blob.pngblob.pngblob.png

Performance parameter Table

                   

   Product Configuration

  Tvis%

U-value(W/m2.K)

 SC

SHGC

  LSG

NFRC2010

EN673




Winter

Summer

Winter

5Optilite S1.16+12Ar+5C+12Ar+5Optilite S1.16

73

0.78

0.82

0.79

0.57

0.50

1.46

5Optilite S1.16+16Ar+5C+16Ar+5Optilite S1.16

73

0.75

0.68

0.65

0.57

0.50

1.46

5Optilite S1.16+18Ar+5C+18Ar+5Optilite S1.16

73

0.77

0.64

0.60

0.58

0.50

1.46

5Optisolar D80+12Ar+5C+12Ar+5Optilite S1.16

64

0.77

0.81

0.77

0.40

0.35

1.83

5Optisolar D80+16Ar+5C+16Ar+5Optilite S1.16

64

0.74

0.67

0.64

0.40

0.35

1.83

5Optisolar D80+18Ar+5C+18Ar+5Optilite S1.16

64

0.76

0.63

0.59

0.40

0.35

1.83

5 Solarban 70XL+12Ar+5C+12Ar+5Optilite S1.16

63

0.75

0.78

0.75

0.32

0.28

2.25

5 Solarban 70XL+16Ar+5C+16Ar+5Optilite S1.16

63

0.73

0.64

0.62

0.32

0.28

2.25

5 Solarban 70XL +18Ar+5C+18Ar+5Optilite S1.16

63

0.74

0.59

0.57

0.32

0.28

2.25